Add to Cart
The programmable electronic load features a voltage and current measurement rate of up to 40KHz
Introduction:
The TDL-6000 series single-channel programmable DC electronic load offers a power range from 150W to 600W, with a resolution of up to 0.1mV/0.1mA. It features dynamic, automatic testing, List, battery, short, and other test functions. It is primarily used for performance testing of batteries, AC-DC/DC-DC modules, chargers, and electronic components, providing the best solution for design R&D and production line testing. The series load can optionally be equipped with RS232/USB/RS485 communication interfaces and comes with powerful control software free of charge, saving secondary development time and making your testing process effortless.
Features:
Specification sheet:
Model | TDL-6015 | TDL-6030 | TDL-6030B | TDL-6030C | |
project | 150W/120V/30A | 300W/120V/30A | 300W/500V /15A | 300W/120V/60A | |
CC mode | range | 0-3A,0-30A | 0-3A,0-30A | 0-3A,0-15A | 0-6A,0-60A |
resolution | 0.1mA,1mA | 0.1mA,1mA | 0.1mA,1mA | 0.1mA,1mA | |
accuracy | 0.05%+0.1%FS 0.1%+0.1%FS | 0.05%+0.1%FS 0.1%+0.1%FS | 0.05%+0.1%FS 0.1%+0.1%FS | 0.1%+0.1%FS, 0.15%+0.25%FS | |
CR mode | range | 0.1-99Ω,100-4KΩ | 0.1-99Ω,100-4KΩ | 0.1-99Ω,100-4KΩ | 0.1-99Ω,100-4KΩ |
resolution | 0.01Ω,1Ω | 0.01Ω,1Ω | 0.01Ω,1Ω | 0.01Ω,1Ω | |
accuracy | 1%+0.3%FS 1%+0.8%FS | 1%+3%FS 1%+0.8%FS | 1%+0.3%FS 1%+0.8%FS | 1%+0.3%FS 1%+0.8%FS | |
CV mode | range | 0-18V,0-120V | 0-18V,0-120V | 0-18V,0-500V | 0-18V,0-120V |
resolution | 1mV,10mV | 1mV,10mV | 1mV,10mV | 1mV,10mW | |
accuracy | 0.05%+0.02%FS 0.05%+0.025%FS | 0.05%+0.02%FS 0.05%+0.025%FS | 0.05%+0.02%FS 0.05%+0.025%FS | 0.05%+0.02%FS 0.05%+0.025%FS | |
CW mode | range | 0-100W,100-150W | 0-100W,100-300W | 0-100W,100-300W | 0-100W,100-300W |
resolution | 1mW,10mW | 1mW,10mW, | 1mW,10mW | 1mW,10mW | |
accuracy | 1%+0.1%FS, | 1%+0.1%FS, | 1%+0.1%FS | 1%+0.1%FS | |
Voltage measurement | range | 0-18V,0-120V | 0.18V,0-120V | 0-18V,0-500V | 0-18V,0-120V |
resolution | 1mV,10mV | 1mV,10mV | 1mV,10mV | 1Mv,10mV | |
accuracy | 0.02%+0.02%FS 0.02%+0.025%FS | 0.02%+0.02%FS 0.02%+0.025%FS | 0.02%+0.02%FS 0.02%+0.025%FS | 0.02% + 0.02%FS 0.02%+0.025%FS | |
Current measurement | range | 0-3A,0-30A | 0-3A,0-30A | 0-3A,0-15A | 0-6A,0-60A |
resolution | 0.1mA,1mA | 0.1mA,1mA | 0.1 mA ,1mA | 0.2 mA ,2mA | |
accuracy | 0.1% + 0.1%FS 0.2%+0.15%FS | 0.1%.+.0.1%FS 0.2%+0.15%FS | 0.1% + 0.1%FS 0.2%+0.3%FS | 0.1%+0.2%FS 0.2%+0.5%FS | |
Short circuit test | Short-circuit current | ≈30A | ≈30A | ≈15A | ≈60A |
Internal resistance | ≈40mΩ | ≈40mΩ | ≈250mΩ | ≈30mΩ | |
Ambient temperature | Operating mode | 0-40℃ | 0-40℃ | 0-40℃ | 0-40℃ |
Battery testing function | capacity | MAX 999AH | MAX999AH | MAX 999AH | MAX 999AH |
Dynamic testing mode | Test rate | 0.1Hz - 1KHz | 1.1HZ-1KHZ | 0.1Hz - 1KHz | 0.1Hz - 1KHz |