Add to Cart
The high-precision TPAD-100 series programmable AC power supply delivers stable output in test indicators
Product Introduction:
The TPAD-100 series high-precision programmable AC/DC power supplies can output the grid voltages of various countries and simulate normal and abnormal conditions of these grids according to relevant standards and regulations. Suitable for high-precision, complex programmable applications in laboratories, production lines, certification bodies, universities, research institutes, etc. It meets IEC standard tests for industries such as new energy, home appliances, military, aviation, etc., fulfilling product design development and certification testing requirements.
Product Features:
TPAD-100 Series Specifications:
Model Numbers | TPAD-110 | TPAD-120 | TPAD-140 | TPAD-160 | |||
Test Functions: | |||||||
Output Modes | AC,DC,AC+DC | ||||||
Programming Features | 9 sets of 8-step gradual changes, steps, sequence tests | ||||||
Waveform Formats | Standard waveforms, harmonic synthesis, pulse waveforms, start/stop angle setting waveforms | ||||||
AC Output Specifications: | |||||||
Output Phases | Single-phase two-wire + PE | ||||||
Rated Power | 1KVA | 2kVA | 4kVA | 6kVA | |||
Output Voltage | Low range | 0.0~150.0V(L-N) Nominal voltage: 125V | |||||
High range | 0.0~300.0V(L-N) Nominal voltage: 250V | ||||||
Voltage Setting Accuracy | Accuracy: ≤0.4% Resolution: 0.1V Rated | ||||||
Rated Current | Low range | 8A | 16A | 32A | 48A | ||
High range | 4A | 8A | 16A | 24A | |||
Peak Current | Low range | 48A | 96A | 192A | 288A | ||
High range | 24A | 48A | 96A | 144A | |||
Output Frequency | 15.0~1000.0Hz | ||||||
Frequency Setting Accuracy | Accuracy: ≤0.15% Resolution: 0.1Hz | ||||||
Voltage Distortion | ≤0.3%@50Hz/60Hz ≤1.0%@15-1kHz | ||||||
Programmable Output Impedance Amplitude | 0Ω+200μH~1Ω+1mH | ||||||
Harmonic Amplitudes | 2-40 times | ||||||
Interharmonic Amplitudes | 15-2400Hz | ||||||
AC Measurement Indicators | |||||||
Voltage Measurement Accuracy | Accuracy: 0.2%FS+0.2% display value Resolution: 0.1V | ||||||
Effective Value Current Measurement Accuracy | Accuracy: 0.3%FS+0.4% display value Resolution: 0.1A | ||||||
Peak Current Measurement Accuracy | Accuracy: 0.6%FS+0.4% display value Resolution: 0.1A | ||||||
Power Measurement Accuracy: Accuracy | 0.4%FS+0.4% display value Resolution: 0.1W | ||||||
Harmonic Measurement Amplitudes | 2-40 times | ||||||
DC Output Specifications: | |||||||
Rated Power | 500W | 1kW | 2kW | 3kW | |||
Output Voltage | Low range | 0.0~212.0V | |||||
High range | 0.0~424.0V | ||||||
Voltage Setting Accuracy | Accuracy: ±1V Resolution: 0.1V | ||||||
Rated Current | Low range | 4A | 8A | 16A | 24A | ||
High range | 2A | 4A | 8A | 12A | |||
Remote Interface: | |||||||
Communication Interfaces | Standard: RS232, Optional: GPIB | ||||||
Input Parameters | |||||||
Input Phases | Single-phase two-wire + PE | ||||||
Input Voltage Range | 90~250V | ||||||
Input Frequency Range | 47~63Hz | ||||||
Input Power Factor | ≥0.97 | ||||||
Operating Environment: | |||||||
Operating Temperature | 0~40℃ | ||||||
Storage Temperature | -40~85℃ | ||||||
Operating Humidity | 30~90%RH (non-condensing) | ||||||
Dimensions (W×H×Dmm) | 483×134×610 | 483×268×610 | 483*356*610 |