Dongguan Chuangrui New Energy Co., Ltd

Value quality, maintain integrity, let products reassure customers, and satisfy customers with services

Manufacturer from China
Verified Supplier
1 Years
Home / Products / AC Power Source /

Integrated AC Dc Current Source Power Supply Testing Analysis Device

Contact Now
Dongguan Chuangrui New Energy Co., Ltd
Visit Website
City:dongguan
Province/State:guangdong
Country/Region:china
Contact Person:MrZou Weimin
Contact Now

Integrated AC Dc Current Source Power Supply Testing Analysis Device

Ask Latest Price
Video Channel
Brand Name :Topfer
Model Number :TPA-200
Place of Origin :China
MOQ :one set
Price :to be discussed
Payment Terms :T/T
Supply Ability :10 sets /30 days
Delivery Time :1 to 2 weeks
Packaging Details :wooden crate
Resolution :0.1V
Line Regulation :0.1%
Accuracy :0.2%+0.2%of F.S.
Power :3/6/9KVA
Temp.coefficient :0.02%per℃
Frequency Range :47∽63Hz
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

The programmable AC power supply is an integrated power testing and analysis device, suitable for R&D characteristic analysis

Output Range:

  • Voltage: 0-150V / 0-300V / Auto (230)
  • 0-150V / 0-300V Parallel (260)
  • 0-300V / 0-500V Series (260)
  • 0-150V / 0-300V (290)

Power:

  • 3000VA, 1φ (230)
  • 6000VA, 1φ (260)
  • 9000VA, 1φ or 3φ (290)

Features:

  • Built-in Direct Digital Synthesis (DDS) waveform generator.
  • High precision measurement functions for voltage, current, peak current, power, frequency, crest factor, power factor, surge current, apparent power (VA), and reactive power (VAR).
  • Power factor correction circuitry to improve input power factor to over 0.98, compliant with IEC standards.
  • Uses Pulse Width Modulation (PWM) technology, resulting in a compact and lightweight design. The output end is equipped with an output relay that can automatically cut off the output when protection is required. This provides a high safety factor.
  • User-settable default voltage and frequency; no editing is needed after startup to output the corresponding voltage and frequency.
  • Generates TTL signals during output changes for use in automatic testing systems.
  • This series of AC power supplies can be remotely controlled via computer through GPIB or RS232 interfaces, featuring parallel and serial communication capabilities, and is compliant with IEEE 488.2 and RS232 communication protocols.

Key Capabilities:

  • This series offers three powerful modes: Step, Pulse, and List modes. Users can program these modes to simulate the desired output waveforms for various applications.
  • Programmable sine wave, square wave, and clipped sine wave outputs.
  • Programmable voltage, frequency, phase, current limiting, and distortion simulation functions.

TPA-200 Series Programmable AC Power Supply Specifications:

(Model) TPA-230 TPA-260 TPA-290
(Output phase) 1 1(Series/Parallel) 1 or 3 Optional
(Output Ratings)
(power) 3000VA 6000VA 3000VA
9000VA
(voltage)
(Range/Phase) 150V/300V/Auto 150V/300V/(Parallel)
300V/500V(Series)
150V/300V
(Accuracy) 0.2%+0.2%of F.S. 0.2%+0.2%of F.S. 0.2%+0.2%of F.S.
(Resolution) 0.1V 0.1V 0.1V
(Distortion*1) 1%(15∽45Hz)
0.5%(>45∽500Hz)
1%(>500∽1kHz)
2%(>1k∽2kHz)
1%(15∽1kHz) 1%(15∽1kHz)
(Line Regulation) 0.1% 0.1% 0.1%
(Load Regulation*2) 0.1% 0.2%(Series),0.8%(Parallel) 0.2%
(Temp.coefficient) 0.02%per℃ 0.02%per℃ 0.02%per℃
(Max.Current/Phase)
(Rms) 30A/15A(150V/300V) 60/30/15A(150/300/500V) 30A/15A(150V/300V)
90A/45A
(Peak) 90A/45A(15∽100Hz)
75A/38A(>100∽1kHz)
60A/30A(>1k∽2kHz)
180/90/45A(45∽100Hz)
150/75/38A(>100∽1kHz)
90A/45A(45∽100Hz)
75A/38A(>100∽1kHz)
(Frequency)
(Range) 15∽2kHz 45∽1kHz 45∽1kHz
(Accuracy) 0.15% 0.15% 0.15%
(Resolution) 0.01Hz(15∽99.9Hz)
0.1Hz(100∽999.9Hz)
0.2Hz(1k∽2kHz)
0.01Hz(45∽99.9Hz)
0.1Hz(100∽999.9Hz)
0.01Hz(45∽99.9Hz)
0.1Hz(100∽999.9Hz)
(Input Ratings)
(Voltage Range) 190∽250v,1Ø 190∽250v,3Ø 190∽250v,3Ø
(Frequency Range) 47∽63Hz 47∽63Hz 47∽63Hz
(Current) 23A max 23A max./phase 23A max./phase
(Power Factor) ≧0.98 (Under full load) ≧0.98 (Under full load) ≧0.98 (Under full load)
(Measurement)
(Voltage /Phase)
(Range) 0∽150V/0∽300V 0∽150V/0∽300V 0∽150V/0∽300V
(Accuracy(rms)) 0.25%+0.1% F.S. 0.25%+0.1% F.S. 0.25%+0.1% F.S.
(Resolution) 0.1V 0.1V 0.1V
(Current/Phase)
(Range(peak) ) 0∽140A 0∽280A 0∽140A
(Accuracy(rms)) 0.4%+0.1% F.S. 0.4%+0.1% F.S. 0.4%+0.1% F.S.
(Accuracy(peak)) 0.4%+0.2% F.S. 0.4%+0.2% F.S. 0.4%+0.2% F.S.
(Resolution) 0.01A 0.01A 0.01A
(Power/phase)
(Accuracy) 1% F.S.(CF<6) 1% F.S.(CF<6) 1% F.S.(CF<6)
(Resolution) 0.01W 0.01W 0.01W
(Frequency)
(Range) 15∽2KHz 45∽1KHz 45∽1KHz
(Accuracy) 0.01%+2 count 0.01%+2 count 0.01%+2 count
(Resolution) 0.01Hz 0.01Hz 0.01Hz
(Others)
(Efficiency) 80% Rated 80% Rated 80% Rated
(Protection)
(Temperature)
(Operating) 0∽40℃ 0∽40℃ 0∽40℃
(Storage) -40∽+85℃ -40∽+85℃ -40∽+85℃
(Safety&EMC)
(Dimension
(H x W x D))
221.5×425×567 mm 445×425×567mm 668×425×567 mm
(Weight) 26.4kg/58.15 lbs 53.8kg/118.50 lbs 81.2kg/178.86 lbs